ZGF-200KV2MA直(zhi)流高壓(ya)發(fa)生器采用(yong)了新(xin)技術、新(xin)材料和新(xin)器件,具有(you)輸(shu)出功(gong)率大、體積小、重(zhong)量(liang)輕的特點(dian),有(you)可靠的過(guo)壓(ya)、過(guo)流及零(ling)位合閘保護功(gong)能,帶(dai)0.75倍電壓(ya)鎖存功(gong)能,并配有(you)時(shi)間繼電器,能在試驗中設置定時(shi)聲訊(xun)報警。整(zheng)個儀器便于(yu)攜帶(dai),操作方便,安全可靠,特別適用(yong)于(yu)電力部門現場試驗。
型號:
瀏覽量:1143
更新時間:2024-04-17
價格:6000
在線留言品牌 | 其他品牌 | 產地類別 | 國產 |
---|---|---|---|
應用領域 | 環保,石油,能源,電子,交通 |
ZGF-200KV2MA 直流高壓發生器講解
ZGF-200KV2MA直流高壓發生器采用了新技(ji)術、新材(cai)料和(he)新器(qi)(qi)件,具有輸出功(gong)率(lv)大、體積(ji)小、重量輕的特(te)點,有可靠的過壓、過流及零位合閘保護功(gong)能,帶0.75倍電壓鎖存功(gong)能,并配有時間繼電器(qi)(qi),能在試驗(yan)(yan)中(zhong)設置定時聲訊報警。整個儀(yi)器(qi)(qi)便于攜(xie)帶,操作方便,安(an)全可靠,特(te)別適用于電力部門(men)現場試驗(yan)(yan)。
ZGF-200KV2MA直流高壓發生器別稱
直(zhi)流(liu)高(gao)(gao)壓(ya)(ya)發(fa)生器(qi)又稱高(gao)(gao)頻、智能直(zhi)流(liu)高(gao)(gao)壓(ya)(ya)發(fa)生器(qi)及直(zhi)流(liu)高(gao)(gao)壓(ya)(ya)發(fa)生裝(zhuang)置,直(zhi)流(liu)高(gao)(gao)壓(ya)(ya)發(fa)生器(qi)
ZGF-200KV2MA直流高壓發生器技術參數
1.技術條件
1)電(dian)源:AC220V±10%,50Hz±1%
2) 輸出(chu)電壓指示精(jing)度:<1級
3) 輸出電流指示精度(du):<1級(ji)
4) 紋波(bo)系數:≤0.5%
5) 0.75倍輸(shu)出(chu)電壓指示(shi)精度:<1級,帶鎖存
2.直流高壓發生器使用(yong)條件
1) 相對濕度:25℃時不(bu)大于85%,無凝露
2) 工作方(fang)式:間斷(duan)使(shi)用30分鐘
3) 環境溫度:- 10 ~ 40℃
4) 海拔高度:1500m以(yi)下
3.直流高壓發生器保護功能
1) 內部(bu)過壓保護, 內部(bu)過流保護
2) 外部(bu)過壓(ya)保(bao)護(hu)(保(bao)護(hu)電壓(ya)可整定), 外部(bu)過流保(bao)護(hu)或擊穿保(bao)護(hu)
3) 內(nei)部功率保(bao)護(hu)
4) 非(fei)零點(dian)啟(qi)動保(bao)護
5) 定(ding)時聲(sheng)訊(xun)報(bao)警(jing)
ZGF-200KV2MA直流(liu)高(gao)壓發生器規(gui)格選型
型號 | 額定輸出直流(liu)電壓(kV) | 額定輸出(chu)直流(liu)電流(liu)(mA) | 額定輸出功率(lv)(W) | 過電壓整定 范圍 (kV) | 重量(kg) | 倍壓箱高度(m) |
60 | 60 | 2 | 120 |
22KV-60KV | 16 | 0.5 |
60 | 5 | 300 | 0.5 | |||
60 | 10 | 600 | 0.5 | |||
120 | 120 | 2 | 240 |
42KV-120KV | 20 | 0.8 |
120 | 5 | 600 | 0.8 | |||
120 | 10 | 1200 | 0.8 | |||
200 | 200 | 2 | 400 |
72KV-200KV | 26 | 1.2 |
200 | 3 | 600 | 1.2 | |||
200 | 5 | 1000 | 1.2 | |||
300 | 300 | 2 | 600 |
100KV-300KV | 31 | 1.7 |
300 | 5 | 1500 | 1.7 | |||
300 | 10 | 3000 | 1.7 |
直流(liu)高(gao)壓發生(sheng)器(qi)原(yuan)理圖
直流高壓發(fa)生器應用(yong)電(dian)力電(dian)子技術(shu),采用(yong)*的(de)(de)PWM調制(zhi)技術(shu)及大功率MOSFET器件,通過中頻倍壓整流而成;該發(fa)生器具(ju)有紋波系數小、輸出(chu)穩定可靠(kao),體積(ji)小、重量輕的(de)(de)特點,且具(ju)有可靠(kao)、靈(ling)敏的(de)(de)內部保護功能(neng),其原理框(kuang)圖(tu)(tu)如圖(tu)(tu)1所(suo)示(shi)。
ZGF系列直流高壓(ya)發生器由控制箱和倍壓(ya)裝置兩(liang)部分(fen)組成,其控制面板(ban)布置如圖(tu)2所(suo)示。
1. 電源(yuan)插座 | 2. 電(dian)源開關 |
3.“電源"指示燈 | 4.“零位"指(zhi)示燈 |
5.“過壓"指示燈 | 6.“過流"指示燈 |
7. 電流顯示表 | 8. 電壓顯示表 |
9. 時(shi)間繼電器 | 10.定時開按鍵 |
11. 0.75倍(bei)電壓顯示表 | 12.接地接線柱 |
13. 信號輸出插座(zuo) | 14.測量輸(shu)入插(cha)座 |
15.“啟動"按鍵 | 16.“停止"按鍵 |
17. 電壓整定(ding)旋(xuan)鈕 | 18.電(dian)壓粗調旋鈕 |
19. 電壓細調(diao)旋(xuan)鈕 | |
ZGF-120KV2MA直流高壓發生器使用方法
如做容性負載試驗時,一定要接上限流電阻。
1.試驗器在使用前應(ying)檢查(cha)其完好性(xing),聯接電纜不應(ying)有斷(duan)路和短路,設備(bei)無破裂等損壞。
2.將機箱、倍壓筒(tong)放置到(dao)合(he)適位(wei)置分別(bie)聯接(jie)好電源線(xian)(xian)、電纜線(xian)(xian)和接(jie)地(di)(di)(di)線(xian)(xian),保護接(jie)地(di)(di)(di)線(xian)(xian)與工作接(jie)地(di)(di)(di)線(xian)(xian)以及放電棒(bang)的接(jie)地(di)(di)(di)線(xian)(xian)均應(ying)單(dan)獨(du)接(jie)到(dao)試品的地(di)(di)(di)線(xian)(xian)上(即一點接(jie)地(di)(di)(di))。嚴禁各接(jie)地(di)(di)(di)線(xian)(xian)相互(hu)串聯。為此,應(ying)使用DHV接(jie)地(di)(di)(di)線(xian)(xian)。
3.電(dian)源開關(guan)放在(zai)關(guan)斷位置(zhi)并檢查調壓電(dian)位器應在(zai)零位。過電(dian)壓保(bao)護整定值一(yi)般為(wei)試驗電(dian)壓的1.1倍。
4.空載升(sheng)壓驗證過電壓保護整定是否靈敏。
5.接通電源(yuan)開關(guan),此時紅(hong)燈亮,表(biao)示電源(yuan)接通。
6.按綠(lv)(lv)色(se)按鈕,則綠(lv)(lv)燈亮,表示高(gao)壓(ya)接通(tong)。
7.順時(shi)針方向平緩調節調壓(ya)(ya)電位器,輸(shu)出端即從零開始升壓(ya)(ya),升至所(suo)需電壓(ya)(ya)后(hou),按規定(ding)時(shi)間記錄電流表(biao)讀數,并(bing)檢查控制箱及(ji)高壓(ya)(ya)輸(shu)出線(xian)有無異常現象(xiang)及(ji)聲(sheng)響(xiang)。
8.降壓(ya),將調壓(ya)電位器回零(ling)后,隨即按紅色按鈕(niu),切斷(duan)高壓(ya)并關閉電源(yuan)開關。
9.對試品(pin)進(jin)行泄漏及(ji)(ji)直流耐(nai)壓試驗(yan)。在進(jin)行檢(jian)查(cha)試驗(yan)確認試驗(yan)器無異常情況(kuang)后(hou),即可開(kai)始(shi)進(jin)行試品(pin)的泄漏及(ji)(ji)直流耐(nai)壓試驗(yan)。將試品(pin)、地線等聯接好,檢(jian)查(cha)無誤(wu)后(hou)即打(da)開(kai)電源。
10.升(sheng)(sheng)壓(ya)(ya)(ya)至(zhi)(zhi)所(suo)需電(dian)(dian)壓(ya)(ya)(ya)或電(dian)(dian)流。升(sheng)(sheng)壓(ya)(ya)(ya)速度以每秒3—5kV試驗(yan)電(dian)(dian)壓(ya)(ya)(ya)為宜。對于(yu)大(da)電(dian)(dian)容(rong)試品(pin)升(sheng)(sheng)壓(ya)(ya)(ya)時(shi)(shi)(shi)(shi)還需監視電(dian)(dian)流表充(chong)電(dian)(dian)電(dian)(dian)流不超過試驗(yan)器的大(da)充(chong)電(dian)(dian)電(dian)(dian)流。對小電(dian)(dian)容(rong)試品(pin)如(ru)氧化鋅避(bi)雷器、磁吹避(bi)雷器等先(xian)升(sheng)(sheng)至(zhi)(zhi)所(suo)需電(dian)(dian)壓(ya)(ya)(ya)(電(dian)(dian)流)的95%,再緩慢仔(zi)細升(sheng)(sheng)至(zhi)(zhi)所(suo)需的電(dian)(dian)壓(ya)(ya)(ya)(電(dian)(dian)流)。然(ran)后(hou)從數顯表上讀(du)出電(dian)(dian)壓(ya)(ya)(ya)(電(dian)(dian)流)值。如(ru)需對氧化鋅避(bi)雷器進行(xing)0.75UDC—1mA測(ce)量時(shi)(shi)(shi)(shi),先(xian)升(sheng)(sheng)至(zhi)(zhi)UDC1mA電(dian)(dian)壓(ya)(ya)(ya)值,然(ran)后(hou)按(an)下黃(huang)色(se)(se)按(an)鈕(niu),此時(shi)(shi)(shi)(shi)電(dian)(dian)壓(ya)(ya)(ya)即(ji)(ji)降至(zhi)(zhi)原(yuan)來的75%,并保持此狀態。此時(shi)(shi)(shi)(shi)可讀(du)取電(dian)(dian)流。測(ce)量完(wan)畢(bi)后(hou),調壓(ya)(ya)(ya)電(dian)(dian)位器逆時(shi)(shi)(shi)(shi)針回到零,按(an)下綠色(se)(se)按(an)鈕(niu)。需再次(ci)升(sheng)(sheng)壓(ya)(ya)(ya)時(shi)(shi)(shi)(shi)按(an)紅色(se)(se)按(an)鈕(niu)即(ji)(ji)可。
必(bi)要時用外接高壓分壓器比對控制箱上的(de)電壓。
11.試驗完畢,降壓(ya),關閉(bi)電源。
12.幾種測量方法
1)一般測量時,當接(jie)好線(xian)后(hou),先把聯接(jie)試(shi)品(pin)的線(xian)懸空(kong),升(sheng)到(dao)試(shi)驗電(dian)壓后(hou)讀取空(kong)試(shi)時的電(dian)暈和雜散電(dian)流(liu)I,然后(hou)接(jie)上(shang)試(shi)品(pin)升(sheng)到(dao)試(shi)驗電(dian)壓讀取總電(dian)流(liu)Ⅰ1;試(shi)品(pin)泄漏(lou)電(dian)流(liu):Io =Ⅰ1—I’
2)當需要測量被試品泄漏電流(liu)時,則應(ying)在高壓(ya)側串入高壓(ya)微安表(見下圖)
微安(an)表(biao)(biao)必(bi)須(xu)有金(jin)屬(shu)屏蔽(bi),應(ying)采用屏蔽(bi)線與試品(pin)(pin)聯(lian)接(jie)。高(gao)(gao)(gao)壓引(yin)線的屏蔽(bi)引(yin)出應(ying)與儀表(biao)(biao)端(duan)的屏蔽(bi)緊密(mi)聯(lian)接(jie)。如(ru)果(guo)試品(pin)(pin)表(biao)(biao)面污穢要排除試品(pin)(pin)表(biao)(biao)面泄(xie)漏電(dian)流的影響可(ke)在試品(pin)(pin)高(gao)(gao)(gao)電(dian)位端(duan)用裸金(jin)屬(shu)軟線緊密(mi)繞幾圈(quan)后與高(gao)(gao)(gao)壓引(yin)線的屏蔽(bi)相聯(lian)接(jie)(見下(xia)圖)。
3)對(dui)氧化(hua)鋅、磁吹避雷器等試(shi)品(pin)接地(di)端可拆開的(de)(de)情況下,也可采用在(zai)試(shi)品(pin)的(de)(de)底(di)部(地(di)電位側)串入(ru)電流表(biao)進行測量(liang)的(de)(de)方式。 當(dang)要排除試(shi)品(pin)表(biao)面泄漏電流的(de)(de)影響,可用軟(ruan)的(de)(de)裸銅(tong)線在(zai)試(shi)品(pin)地(di)電位端繞上幾(ji)圈并與屏蔽線的(de)(de)屏蔽相(xiang)聯接(見下圖)
13.對于氧化鋅避雷器等小電(dian)(dian)(dian)(dian)容試(shi)(shi)品(pin)一般通過測壓(ya)電(dian)(dian)(dian)(dian)阻(zu)放(fang)電(dian)(dian)(dian)(dian)時間很快。而(er)對電(dian)(dian)(dian)(dian)纜等大電(dian)(dian)(dian)(dian)容試(shi)(shi)品(pin)一般要(yao)待(dai)試(shi)(shi)品(pin)電(dian)(dian)(dian)(dian)壓(ya)自放(fang)電(dian)(dian)(dian)(dian)至試(shi)(shi)驗電(dian)(dian)(dian)(dian)壓(ya)的(de)(de)(de)20%以下(xia),再通過配套的(de)(de)(de)放(fang)電(dian)(dian)(dian)(dian)棒進行(xing)放(fang)電(dian)(dian)(dian)(dian)。待(dai)試(shi)(shi)品(pin)充分放(fang)電(dian)(dian)(dian)(dian)后掛好(hao)接地線(xian),才允許(xu)進行(xing)高(gao)壓(ya)引線(xian)的(de)(de)(de)拆除和(he)更(geng)換(huan)接線(xian)工(gong)作。
14.保(bao)護動(dong)作后(hou)的操(cao)作
在使用(yong)過程中發現綠燈(deng)滅,紅燈(deng)亮,電(dian)壓(ya)(ya)下降,即為有關(guan)保護動(dong)作(zuo)。此時應(ying)關(guan)閉電(dian)源開(kai)(kai)(kai)關(guan),面板指示燈(deng)均不亮。將調壓(ya)(ya)電(dian)位器(qi)退回零位,一分(fen)鐘后(hou)待(dai)機(ji)內低壓(ya)(ya)電(dian)容(rong)器(qi)充分(fen)放電(dian)后(hou)才允(yun)許再(zai)次打開(kai)(kai)(kai)電(dian)源開(kai)(kai)(kai)關(guan)。重新進行空(kong)載試(shi)驗(yan)并查明情(qing)況后(hou)可(ke)再(zai)次升(sheng)壓(ya)(ya)試(shi)驗(yan)。