FL2-100A-75MV分流(liu)器是測量直流(liu)電(dian)(dian)流(liu)用(yong)的,根(gen)據(ju)直流(liu)電(dian)(dian)流(liu)通(tong)過電(dian)(dian)阻(zu)時(shi)在(zai)電(dian)(dian)阻(zu)兩端產生(sheng)電(dian)(dian)壓的原(yuan)理(li)制成(cheng)(cheng)。100A分流(liu)器是測量直流(liu)電(dian)(dian)流(liu)用(yong)的,根(gen)據(ju)直流(liu)電(dian)(dian)流(liu)通(tong)過電(dian)(dian)阻(zu)時(shi)在(zai)電(dian)(dian)阻(zu)兩端產生(sheng)電(dian)(dian)壓的原(yuan)理(li)制成(cheng)(cheng)。
型號:
瀏覽量:2016
更新時間:2023-11-02
在線留言品牌 | 其他品牌 | 產地類別 | 國產 |
---|---|---|---|
應用領域 | 石油,能源,電子,交通 |
FL2-100A-75MV分流器
FL2-100A-75MV分流器
分流器
分流器原理及接線方法
分流器定義:
分流器實際就是一個阻值很小的電(dian)阻,當(dang)有(you)直流電(dian)流通(tong)過時,產生壓降,供直流電(dian)流表顯示;
直(zhi)流電流表實際是電壓(ya)表,滿度值(zhi)75mV;
直流電流表和(he)分流器(qi)是(shi)配套使用的;
比如:100A電流(liu)表配套的分流(liu)器阻(zu)值為0.00075歐;
即100A*0.00075歐=75mV;
50A電流表配套(tao)的分流器阻值(zhi)為0.0015歐;
50A*0.0015歐=75mV。
二,分離器測量:
要(yao)測(ce)量(liang)(liang)(liang)一個(ge)很大(da)(da)的(de)(de)直(zhi)流(liu)(liu)電(dian)(dian)流(liu)(liu),例如幾十(shi)安培(pei),甚至更大(da)(da),幾百(bai)安培(pei),沒有那(nei)么(me)大(da)(da)量(liang)(liang)(liang)程的(de)(de)電(dian)(dian)流(liu)(liu)表(biao)進行電(dian)(dian)流(liu)(liu)的(de)(de)測(ce)量(liang)(liang)(liang),怎么(me)辦(ban)?這(zhe)(zhe)就要(yao)采用分流(liu)(liu)器.分流(liu)(liu)器是(shi)一個(ge)可以通過大(da)(da)電(dian)(dian)流(liu)(liu)的(de)(de)電(dian)(dian)阻,當電(dian)(dian)流(liu)(liu)流(liu)(liu)過分流(liu)(liu)器時(shi),在它的(de)(de)兩(liang)端就會出現一個(ge)毫伏(fu)級的(de)(de)電(dian)(dian)壓,于是(shi)用毫伏(fu)電(dian)(dian)壓表(biao)來測(ce)量(liang)(liang)(liang)這(zhe)(zhe)個(ge)電(dian)(dian)壓,再將這(zhe)(zhe)個(ge)電(dian)(dian)壓換算(suan)成電(dian)(dian)流(liu)(liu).就完成了大(da)(da)電(dian)(dian)流(liu)(liu)的(de)(de)測(ce)量(liang)(liang)(liang)。
電流(liu)表(biao)(biao)有(you)多種不(bu)同規格,但是(shi)實(shi)際表(biao)(biao)頭卻是(shi)標準的毫伏電壓表(biao)(biao)。比如是(shi)一(yi)種滿(man)刻度為(wei)75mv的電壓表(biao)(biao)。 那么用這塊電壓表(biao)(biao)測量比如20A的電流(liu),就需要給它(ta)配(pei)一(yi)個在流(liu)過20A電流(liu)時候產生75mv電壓降的分流(liu)電阻,也稱(cheng)75mv分流(liu)器。
分(fen)流(liu)(liu)(liu)(liu)器就是一(yi)個能夠通(tong)過極大(da)電(dian)(dian)流(liu)(liu)(liu)(liu)的(de)(de)電(dian)(dian)阻一(yi)般常用(yong)的(de)(de)1或20A以(yi)及3的(de)(de)電(dian)(dian)流(liu)(liu)(liu)(liu)表(biao)都需要(yao)分(fen)流(liu)(liu)(liu)(liu)器,分(fen)流(liu)(liu)(liu)(liu)器的(de)(de)阻抗(kang)(kang)=表(biao)頭標志滿(man)度(du)電(dian)(dian)壓/表(biao)頭滿(man)度(du)電(dian)(dian)流(liu)(liu)(liu)(liu)。比如20A的(de)(de)電(dian)(dian)流(liu)(liu)(liu)(liu)表(biao)的(de)(de)分(fen)流(liu)(liu)(liu)(liu)器阻值=75mv*10-3/20A=0.00375Ω,阻抗(kang)(kang)恒定后根據(ju)歐姆(mu)定律U=IR,電(dian)(dian)流(liu)(liu)(liu)(liu)與(yu)電(dian)(dian)壓成正比,電(dian)(dian)流(liu)(liu)(liu)(liu)為線形(xing)電(dian)(dian)壓也(ye)呈(cheng)線形(xing),所以(yi)就可以(yi)用(yong)一(yi)個滿(man)度(du)為75mv的(de)(de)電(dian)(dian)壓表(biao)顯示(shi)當前(qian)電(dian)(dian)流(liu)(liu)(liu)(liu)。因此,使用(yong)的(de)(de)電(dian)(dian)流(liu)(liu)(liu)(liu)表(biao)實際是一(yi)塊電(dian)(dian)壓表(biao)。
交(jiao)流大(da)(da)電(dian)(dian)(dian)(dian)流怎(zen)么(me)測(ce)(ce)量呢?采用(yong)電(dian)(dian)(dian)(dian)流互感器,將大(da)(da)電(dian)(dian)(dian)(dian)流以一定變(bian)比(bi)變(bian)成(cheng)5安培以下的(de)小電(dian)(dian)(dian)(dian)流,于是用(yong)小量程交(jiao)流電(dian)(dian)(dian)(dian)流表就(jiu)可測(ce)(ce)量大(da)(da)電(dian)(dian)(dian)(dian)流了,只是測(ce)(ce)得的(de)電(dian)(dian)(dian)(dian)流還要(yao)乘那個變(bian)比(bi)。
就是一根(gen)短(duan)的(de)(de)導體,可以是各種(zhong)金(jin)屬或合金(jin)的(de)(de),也連(lian)接端子;其(qi)直流(liu)電(dian)(dian)(dian)阻是嚴格調好(hao)的(de)(de);串接在直流(liu)電(dian)(dian)(dian)路(lu)里,直流(liu)電(dian)(dian)(dian)流(liu)過分(fen)(fen)流(liu)器,分(fen)(fen)流(liu)器兩端產(chan)生毫(hao)伏(fu)級直流(liu)電(dian)(dian)(dian)壓(ya)信號,使(shi)并接在該分(fen)(fen)流(liu)器兩端的(de)(de)計量表(biao)指(zhi)(zhi)針擺動,該讀數就是該直流(liu)電(dian)(dian)(dian)路(lu)里的(de)(de)電(dian)(dian)(dian)流(liu)值。所謂分(fen)(fen)流(liu),即分(fen)(fen)一小的(de)(de)電(dian)(dian)(dian)流(liu)去推(tui)動表(biao)指(zhi)(zhi)示,該小電(dian)(dian)(dian)流(liu)(mA)與大回路(lu)里的(de)(de)電(dian)(dian)(dian)流(liu)(1A-幾十A)比例越小,電(dian)(dian)(dian)流(liu)表(biao)指(zhi)(zhi)示讀數的(de)(de)線性就越好(hao),也更。這(zhe)是電(dian)(dian)(dian)工電(dian)(dian)(dian)路(lu)的(de)(de)常用產(chan)品,防雷有分(fen)(fen)流(liu)措(cuo)施。
三,分流器選型敘述:
FL-2型系列250A/75mV和300A/75mV分(fen)流器主要由(you)錳(meng)銅片(pian)(Cu-Mn)和銅接(jie)(jie)(jie)(jie)頭焊接(jie)(jie)(jie)(jie)構成(cheng),在(zai)分(fen)流器兩端的(de)接(jie)(jie)(jie)(jie)頭上有兩組(zu)接(jie)(jie)(jie)(jie)線端鈕(niu):外邊一組(zu)為(wei)電位(wei)端鈕(niu),供(gong)與(yu)電源(yuan)線連接(jie)(jie)(jie)(jie),內(nei)邊一組(zu)為(wei)電位(wei)端鈕(niu)供(gong)與(yu)測(ce)量儀表連接(jie)(jie)(jie)(jie),本(ben)公(gong)司專業生產各(ge)類固定(ding)式定(ding)值分(fen)流器和精密合金電阻器的(de)電參(can)數和尺寸,同時我們能為(wei)客戶定(ding)做不同款式(包括出口型)的(de)特(te)殊分(fen)流器.如(ru)有特(te)殊要求可訂制(zhi)訂貨。高于150A/75mV的(de)分(fen)流器如(ru)仍(reng)然需要增加底座隔離,本(ben)公(gong)司通(tong)常使用耐高溫(wen)材料( 美(mei)國杜邦(bang):HTNFR52G15BL,熔點:310度 防火V0 注塑級)
FL-2型系列(lie)分流器(qi)其精度(du)為(wei):0.5級,規格(ge)范圍(wei)有(you):1A-15000A,二次電壓:20mV、30mV、50mV、60mV、75mV、100mV、150mV等(deng),常規為(wei)75mV。通常2000A以上都改(gai)良為(wei)FL-29型或FL-39型外徑尺寸(cun)。
一.產品用途:分流器廣(guang)泛(fan)用于擴大儀表測量電(dian)流范圍,均(jun)可用于通訊系統(tong)
電子整機自動(dong)化控制的電源(yuan)等回路作(zuo)限流.均流.取樣.檢測作(zuo)用(yong),使(shi)用(yong)條件為 B
組。
二.主要技術參數:
1.準(zhun)確度等級:5~4000A:0.5 級,5000A~10000A:1 級。
2.使用環境條件: -40~+60℃,相對濕度≤95%(35℃)
3.耐機械性能(neng):能(neng)承受加速度為 70 米/秒(miao)及沖擊(ji)頻率每分鐘
80~120 次 6 小時的運輸顛震。
4.超(chao)載(zai)性(xing)能:額定電(dian)流 120%,2 小時(shi)。
5.電壓降(jiang):50mV,75mV,100mV,200mV,300mV.
6.負載下發熱:溫升(sheng)變化趨穩定電(dian)流(liu) 50A 以下不超過 80℃。 額定電(dian)流(liu) 50A 以上不超過 120℃。
三.分流器型號(hao)表示(shi)規則:
FL-2 200A 75mV 0.5%
(型號(hao)) (電流) (壓降) (精度)
四.分流器原理及接線方法
|
100A分流器 的詳細介紹
100A分流器是測(ce)量直流電(dian)流用的(de),根據(ju)直流電(dian)流通過電(dian)阻(zu)時在電(dian)阻(zu)兩端產生電(dian)壓(ya)的(de)原理(li)制成。
100A分流器的詳細介紹:
100A分流器技術參數表:
種類50mv 規格TYPE | 總長L1 | 寬W | 安裝孔距 W1 | 高H1 | 高H2 | 大孔徑 M3 | M1 | M2 | 重量g |
1A~100A | 66 | 32 | 22 | 28 | 11 | 4.5 | 3 | 5 | 100 |
150A | 66 | 32 | 22 | 30 | 11 | 4.5 | 3 | 5 | 100 |
200A | 66 | 32 | 22 | 33 | 11 | 4.5 | 3 | 5 | 100 |