国产精品三级在线观看无码_jizzjizzjizz亚洲熟妇_丰满人妻被黑人猛烈进入_久久精品国产亚洲αv忘忧草

首頁 > 產品中心 > 便攜式動平衡測量儀>現場動平衡測量儀 > VT700現場(chang)動(dong)平衡測(ce)量(liang)儀

VT700現場動平衡測量儀

簡要描述:

VT700現(xian)場動(dong)(dong)(dong)平(ping)衡測量(liang)儀可以對各種旋(xuan)轉機(ji)械進(jin)行(xing)整機(ji)現(xian)場動(dong)(dong)(dong)平(ping)衡,相當于(yu)一(yi)臺可移動(dong)(dong)(dong)的動(dong)(dong)(dong)平(ping)衡機(ji)。它設計精(jing)巧攜帶(dai)方(fang)便(bian),整個儀器裝在一(yi)只便(bian)攜儀器箱內。 VT800除具有一(yi)般的動(dong)(dong)(dong)平(ping)衡功(gong)能外,還針對臥式(shi)螺旋(xuan)離心機(ji)、碟(die)式(shi)離心機(ji)類(lei)產品的整機(ji)動(dong)(dong)(dong)平(ping)衡進(jin)行(xing)特殊設計, 増加了抗干擾能力,能夠很方(fang)便(bian)的測量(liang)有差轉速復合(he)轉鼓體的振動(dong)(dong)(dong)及進(jin)行(xing)整機(ji)現(xian)場動(dong)(dong)(dong)平(ping)衡.

型號:

瀏覽量:1149

更新時間:2023-11-06

價格:

在線留言
品牌其他品牌產地類別國產
應用領域環保,石油,能源,電子,交通

VT700現場動平衡測量儀

VT700現場動平衡測量儀

VT700低轉速雙面動平衡儀具有一般的動平衡功能外,還針對臥式螺旋離心機、碟式離心機類產品的整機動平衡進行特殊設計, 増加了抗干擾能力,能夠很方便的測量有差轉速復合轉鼓體的振動及進行整機現場動平衡.
動平衡儀是轉速表、是測振儀、特別是高水平的現場動平衡儀!
▲ 具有動平衡測試,給出轉速、總振幅、選取頻振幅和相位角(相對光電參數標志),這是一般動平衡儀功能。
▲ 具有用試重測量影響(xiang)系(xi)數(shu)并計算單測點

技術(shu)參數

1.一般測量:

轉(zhuan)速(su)測量(liang):           30~30,000 rpm  

振(zhen)動(dong)測量:        ;   0.01~5000μm (峰峰值)

0.01~2000mm/s (有效值(zhi))

振動分(fen)析:           FFT  頻(pin)譜(pu)分(fen)析

顯示方式(shi):           點(dian)陣圖形(xing)(xing) 64X240點(dian)陣圖形(xing)(xing)液晶(jing)漢(han)化(hua)菜

鍵   盤:            八(ba)鍵  

2.動平衡測(ce)量:

測量點數(shu):         單(dan)測點或單(dan)面(mian)  雙測點或雙面(mian)

振動信號頻帶:       3Hz~1KHz

同頻(pin)工(gong)作轉速:       180~30,000 rpm

同頻振幅(fu)量程:       0.01~5000μm  (峰(feng)峰(feng)值(zhi))

振動(dong)烈度量程:       0.01~2000mm/s  (有(you)效(xiao)值)

相位精度(du):           0-360°±1 °

不平衡量(liang)減(jian)少率:    ≥95%

動(dong)平(ping)衡測量中(zhong)的若干問題

6.1、確認轉子設備(bei)是否(fou)有不平衡引起振動

  首先要確認轉子(zi)設備(bei)是否存在不(bu)平(ping)衡(heng)引起振(zhen)動(dong)(dong)。現場設備(bei)的(de)振(zhen)動(dong)(dong)是復雜的(de),一般混(hun)頻(pin)振(zhen)動(dong)(dong)。只有(you)在不(bu)平(ping)衡(heng)振(zhen)動(dong)(dong)分(fen)(fen)(fen)量(liang)(liang)占(zhan)混(hun)頻(pin)總(zong)振(zhen)動(dong)(dong)量(liang)(liang)的(de)80%以(yi)上(shang),使(shi)用(yong)本儀器(qi)才能看到(dao)效(xiao)果。具體(ti)(ti)說運用(yong)本儀器(qi)的(de)“信號(hao)分(fen)(fen)(fen)析(xi)"里“FFT分(fen)(fen)(fen)析(xi)"功能,對振(zhen)動(dong)(dong)信號(hao)進行(xing)頻(pin)譜(pu)分(fen)(fen)(fen)析(xi)。通過頻(pin)譜(pu)分(fen)(fen)(fen)析(xi),如果基頻(pin)的(de)振(zhen)動(dong)(dong)量(liang)(liang)很(hen)大(da),其他倍頻(pin)振(zhen)動(dong)(dong)量(liang)(liang)都很(hen)小(xiao),甚至(zhi)沒有(you)。運用(yong)本儀器(qi)的(de)操作(zuo)就(jiu)能達到(dao)令(ling)人滿意(yi)的(de)效(xiao)果。

6.2、動(dong)平衡儀對設備的基(ji)本要求

動平衡儀對(dui)機器設(she)備的基本要求:在工作轉速范圍內(nei),能夠進行多次啟(qi)停機(ji)運轉。具體說(shuo)用試重(zhong)法,對單面(mian)平衡至(zhi)少需要(yao)開(kai)(kai)3次機(ji),對雙面(mian)平衡至(zhi)少需要(yao)開(kai)(kai)4次機(ji),才能看到動平衡的效果(guo)。能夠便利在現(xian)場對轉(zhuan)(zhuan)子進行(xing)加(jia)重(zhong)或(huo)去(qu)重(zhong)工作(zuo)。一切密封(feng)的旋轉(zhuan)(zhuan)轉(zhuan)(zhuan)子或(huo)軸系或(huo)不允許在轉(zhuan)(zhuan)子校正平(ping)面上加(jia)重(zhong)或(huo)去(qu)重(zhong),是(shi)無法進行(xing)動(dong)平(ping)衡操作(zuo)。現場能方(fang)便安裝傳(chuan)(chuan)感(gan)器(qi)(qi),單面平衡(heng)需求(qiu)(qiu)一個(ge)轉速傳(chuan)(chuan)感(gan)器(qi)(qi)和一個(ge)振動傳(chuan)(chuan)感(gan)器(qi)(qi),雙面平衡(heng)需求(qiu)(qiu)一個(ge)轉速傳(chuan)(chuan)感(gan)器(qi)(qi)和二個(ge)振動傳(chuan)(chuan)感(gan)器(qi)(qi)。這些是動平衡(heng)儀測量(liang)的先決條件。

6.3、如何提高動平衡(heng)儀(yi)測量精度

動(dong)(dong)(dong)平(ping)(ping)(ping)衡(heng)(heng)儀不(bu)同(tong)于動(dong)(dong)(dong)平(ping)(ping)(ping)衡(heng)(heng)機(ji)。動(dong)(dong)(dong)平(ping)(ping)(ping)衡(heng)(heng)機(ji)既(ji)有(you)(you)電控(kong)部(bu)(bu)(bu)分(fen),又有(you)(you)支撐(cheng)轉子(zi)運(yun)轉的(de)(de)(de)(de)機(ji)械部(bu)(bu)(bu)分(fen)。動(dong)(dong)(dong)平(ping)(ping)(ping)衡(heng)(heng)儀只(zhi)(zhi)有(you)(you)電控(kong)部(bu)(bu)(bu)分(fen),其支撐(cheng)轉子(zi)運(yun)轉的(de)(de)(de)(de)機(ji)械部(bu)(bu)(bu)分(fen)是由各(ge)家用(yong)戶(hu)提供(gong)的(de)(de)(de)(de);現(xian)場(chang)有(you)(you)進口(kou)設(she)(she)(she)(she)備(bei)(bei)(bei)(bei);有(you)(you)國產(chan)(chan)設(she)(she)(she)(she)備(bei)(bei)(bei)(bei);有(you)(you)各(ge)廠自(zi)己(ji)生(sheng)產(chan)(chan)的(de)(de)(de)(de)設(she)(she)(she)(she)備(bei)(bei)(bei)(bei);有(you)(you)臨時(shi)焊接(jie)的(de)(de)(de)(de)設(she)(she)(she)(she)備(bei)(bei)(bei)(bei),各(ge)種設(she)(she)(she)(she)備(bei)(bei)(bei)(bei)機(ji)械加(jia)工的(de)(de)(de)(de)精(jing)(jing)(jing)(jing)度各(ge)不(bu)相同(tong),差別(bie)很大(da)。另外現(xian)場(chang)測試環境也(ye)是不(bu)同(tong)的(de)(de)(de)(de)有(you)(you)的(de)(de)(de)(de)干擾大(da),有(you)(you)的(de)(de)(de)(de)干擾小。這就(jiu)造成平(ping)(ping)(ping)衡(heng)(heng)儀到(dao)各(ge)廠家測量(liang)(liang)精(jing)(jing)(jing)(jing)度的(de)(de)(de)(de)不(bu)同(tong),無(wu)法(fa)給(gei)出一個統(tong)一的(de)(de)(de)(de)測量(liang)(liang)精(jing)(jing)(jing)(jing)度標(biao)準。在本儀器中(zhong)只(zhi)(zhi)有(you)(you)一個技術(shu)指(zhi)(zhi)標(biao),不(bu)平(ping)(ping)(ping)衡(heng)(heng)量(liang)(liang)減少(shao)率≥85%,這個指(zhi)(zhi)標(biao)也(ye)是比較籠(long)統(tong)的(de)(de)(de)(de)。在進口(kou)設(she)(she)(she)(she)備(bei)(bei)(bei)(bei);國產(chan)(chan)設(she)(she)(she)(she)備(bei)(bei)(bei)(bei)中(zhong)能夠達到(dao)這個指(zhi)(zhi)標(biao),對(dui)各(ge)廠自(zi)己(ji)生(sheng)產(chan)(chan)的(de)(de)(de)(de)設(she)(she)(she)(she)備(bei)(bei)(bei)(bei)只(zhi)(zhi)能接(jie)近這個指(zhi)(zhi)標(biao),對(dui)現(xian)場(chang)臨時(shi)焊接(jie)的(de)(de)(de)(de)設(she)(she)(she)(she)備(bei)(bei)(bei)(bei)則是很難(nan)達這個指(zhi)(zhi)標(biao)。總之動(dong)(dong)(dong)平(ping)(ping)(ping)衡(heng)(heng)儀測量(liang)(liang)精(jing)(jing)(jing)(jing)度取決于支撐(cheng)轉子(zi)運(yun)轉的(de)(de)(de)(de)設(she)(she)(she)(she)備(bei)(bei)(bei)(bei)的(de)(de)(de)(de)精(jing)(jing)(jing)(jing)度等級(ji),設(she)(she)(she)(she)備(bei)(bei)(bei)(bei)的(de)(de)(de)(de)精(jing)(jing)(jing)(jing)度等級(ji)越高,動(dong)(dong)(dong)平(ping)(ping)(ping)衡(heng)(heng)儀測量(liang)(liang)精(jing)(jing)(jing)(jing)度也(ye)越高。用(yong)我單位動(dong)(dong)(dong)平(ping)(ping)(ping)衡(heng)(heng)儀,用(yong)動(dong)(dong)(dong)平(ping)(ping)(ping)衡(heng)(heng)機(ji)的(de)(de)(de)(de)機(ji)械部(bu)(bu)(bu)分(fen),同(tong)樣可以達到(dao)動(dong)(dong)(dong)平(ping)(ping)(ping)衡(heng)(heng)機(ji)的(de)(de)(de)(de)技術(shu)指(zhi)(zhi)示,這毫無(wu)疑義(yi)的(de)(de)(de)(de)。

6.4、動平衡儀與動平衡機的(de)區別

現場動平衡(heng)儀的優點:現場平衡是在(zai)*裝配(pei)好的機器上進行的,可以補償裝配(pei)上的誤差。不必拆(chai)卸機器(qi)和運(yun)輸轉子(zi)到動平衡(heng)機。節省時(shi)間;降低費用;減少停機損失(shi)。現(xian)場動平衡(heng)儀可以平衡(heng)任何重(zhong)量和體(ti)(ti)積大(da)小轉子。動平衡(heng)機則(ze)對(dui)轉子重(zhong)量和尺寸是(shi)有一定(ding)規定(ding)要求的(de)。較低的投資成本,動平衡機少則(ze)幾萬多(duo)則(ze)十(shi)幾萬元(yuan),一臺便(bian)攜式動平衡儀一般都在1萬元(yuan)以下(xia)。

6.5、三種轉速傳感器(qi)的比較

轉(zhuan)速傳感(gan)器(qi)有霍爾(er)轉(zhuan)速傳感(gan)器(qi),光電(dian)轉(zhuan)速傳感(gan)器(qi)以及激光轉(zhuan)速傳感(gan)器(qi)(選配件)。

本儀器(qi)配套(tao)發貨是霍(huo)爾傳(chuan)感器(qi)。霍(huo)爾傳(chuan)感器(qi)的優點是;輸(shu)出脈沖好,測量精度高(gao),抗干(gan)擾能力強,現場安裝簡單。對(dui)準配套(tao)小磁鋼后,測量過程中不(bu)要做任何調整,方(fang)便可(ke)靠。缺(que)點是:小磁鋼在高(gao)速旋(xuan)轉時會飛(fei)出來。如果平面上有(you)(you)孔;有(you)(you)槽;有(you)(you)飛(fei)沿,用502膠水貼牢,zui高(gao)轉速大約(yue)40005000轉(zhuan)(zhuan)。轉(zhuan)(zhuan)速在3000轉(zhuan)(zhuan)以下用502膠(jiao)水筒(tong)單(dan)處理一下就可(ke)以用。

光(guang)電轉(zhuan)(zhuan)速傳感器(qi)的優點是;測(ce)量(liang)轉(zhuan)(zhuan)速時只貼(tie)一張反(fan)光(guang)紙(zhi),沒有任何(he)附加質量(liang)。缺點是:易受(shou)光(guang)線的干擾。要求在轉(zhuan)(zhuan)軸上(shang)貼(tie)的反(fan)光(guang)紙(zhi),并(bing)且黑白(bai)分明,邊緣齊(qi)整(zheng),用反(fan)光(guang)紙(zhi)效果。光(guang)電傳感器(qi)對(dui)準(zhun)反(fan)光(guang)紙(zhi)后,真正運轉(zhuan)(zhuan)測(ce)試(shi)中還要調(diao)節傳感器(qi)的距離(li)和靈(ling)敏度,不(bu)夠(gou)安全。高速時讀(du)數易跳動,zui多可以(yi)測(ce)到10000轉(zhuan)(zhuan)。

相比光電傳感(gan)(gan)器(qi),霍爾傳感(gan)(gan)器(qi)測量轉速(su)的范圍很廣,抗(kang)外部環(huan)境干擾能力強,現場(chang)安裝簡單。我(wo)們推薦(jian):在能夠用霍爾傳感(gan)(gan)器(qi)場(chang)合盡量用它(ta)。

用(yong)戶(hu)根據(ju)機器(qi)設備的(de)實際轉速,任選一種。

激(ji)光轉(zhuan)速(su)傳感(gan)器(qi)近新(xin)發展起來一種(zhong)轉(zhuan)速(su)傳感(gan)器(qi),zui高轉(zhuan)速(su)可以測到60000轉(zhuan),適用(yong)于高速(su)測量(liang)。其測試方(fang)法(fa)與光電(dian)轉(zhuan)速(su)傳感(gan)器(qi)一樣。比光電(dian)轉(zhuan)速(su)傳感(gan)器(qi)抗干擾能力強(qiang),測量(liang)距離(li)遠,讀數穩定可靠。只是(shi)價格(ge)比較貴,需要單獨購買。

6.6、如何克服小磁鋼附(fu)加質(zhi)量的影響

使用霍爾轉速傳感(gan)器,需要配(pei)套小(xiao)磁鋼(gang)作為標志。小(xiao)磁鋼(gang)本(ben)身是(shi)一個質量塊,有一定(ding)附加(jia)質量,對平衡(heng)精度要求高的(de)用戶是(shi)不容許的(de)。解決的(de)方法是(shi)在(zai)同半徑對面的(de)位置(zhi)(相差180°位置),反(fan)貼(tie)一(yi)個同樣的小(xiao)磁(ci)鋼(gang)。正貼(tie)小(xiao)磁(ci)鋼(gang)測轉速,反(fan)貼(tie)小(xiao)磁(ci)鋼(gang)抵(di)消附加質(zhi)量。另外(wai)安放小(xiao)磁(ci)鋼(gang)半徑盡量小(xiao)一(yi)點也可以減(jian)少小(xiao)磁(ci)鋼(gang)附加質(zhi)量的影響(xiang)。

6.7、傳感器數值穩(wen)定是動平衡(heng)測(ce)量的關(guan)鍵

傳(chuan)感(gan)(gan)(gan)器(qi)(qi)數(shu)(shu)值(zhi)(zhi)(zhi)穩定(ding),包(bao)括轉速(su)(su)數(shu)(shu)值(zhi)(zhi)(zhi)穩定(ding)和振動數(shu)(shu)值(zhi)(zhi)(zhi)穩定(ding)。使用霍爾轉速(su)(su)傳(chuan)感(gan)(gan)(gan)器(qi)(qi)或(huo)激光(guang)轉速(su)(su)傳(chuan)感(gan)(gan)(gan)器(qi)(qi)數(shu)(shu)值(zhi)(zhi)(zhi)的(de)(de)穩定(ding)是很容易。使用光(guang)電(dian)(dian)轉速(su)(su)傳(chuan)感(gan)(gan)(gan)器(qi)(qi)數(shu)(shu)值(zhi)(zhi)(zhi)不穩定(ding),需要重新做光(guang)電(dian)(dian)標志,調節光(guang)電(dian)(dian)傳(chuan)感(gan)(gan)(gan)器(qi)(qi)與光(guang)標紙的(de)(de)距離以及傳(chuan)感(gan)(gan)(gan)器(qi)(qi)上(shang)靈(ling)敏度旋鈕。另外還要注(zhu)意每次設備(bei)開機,轉速(su)(su)測(ce)量值(zhi)(zhi)(zhi)要基本(ben)*,變化值(zhi)(zhi)(zhi)在10轉以內。振動傳(chuan)感(gan)(gan)(gan)器(qi)(qi)測(ce)量數(shu)(shu)值(zhi)(zhi)(zhi)不穩定(ding)。解決的(de)(de)方法(fa)是:振動傳感器要求安裝(zhuang)在軸承座平(ping)面(mian)上(shang),并(bing)且越(yue)(yue)靠近(jin)軸承座越(yue)(yue)好。在動平衡(heng)萊單(dan)圖5-6帶(dai)寬選(xuan)擇中選(xuan)用窄帶(dai)濾波,增加抗干擾能力。對轉(zhuan)子旋(xuan)轉(zhuan)的(de)機(ji)器設備(bei),增加其(qi)剛性(xing)支撐(cheng),加強(qiang)設備(bei)底(di)腳(jiao)安裝固定(ding)(ding)。在設備(bei)的(de)底(di)部采取(qu)減振(zhen)措施。保(bao)證振(zhen)動的(de)幅值(zhi)與相角(jiao)讀數只在個位(wei)上數變化(hua),十位(wei)上數基本不變化(hua)。傳感器數值(zhi)穩定(ding)(ding)是動平衡結(jie)果重復性(xing)好,誤差小的(de)關鍵。

6.8、試重(zhong)法中試重(zhong)的重(zhong)量和角度的確定

試(shi)(shi)(shi)重(zhong)(zhong)(zhong)(zhong)(zhong)法(fa)(fa)動平(ping)衡工作需(xu)要試(shi)(shi)(shi)加(jia)(jia)(jia)(jia)重(zhong)(zhong)(zhong)(zhong)(zhong),根據加(jia)(jia)(jia)(jia)重(zhong)(zhong)(zhong)(zhong)(zhong)前(qian)后(hou)的(de)(de)(de)振(zhen)(zhen)動變化計算出應加(jia)(jia)(jia)(jia)重(zhong)(zhong)(zhong)(zhong)(zhong)量與相角(jiao)。試(shi)(shi)(shi)重(zhong)(zhong)(zhong)(zhong)(zhong)塊重(zhong)(zhong)(zhong)(zhong)(zhong)量大(da)(da)小的(de)(de)(de)選(xuan)擇很重(zhong)(zhong)(zhong)(zhong)(zhong)要。試(shi)(shi)(shi)重(zhong)(zhong)(zhong)(zhong)(zhong)塊重(zhong)(zhong)(zhong)(zhong)(zhong)量重(zhong)(zhong)(zhong)(zhong)(zhong)了(le),有可(ke)(ke)能導致(zhi)機器振(zhen)(zhen)動過大(da)(da),損壞設(she)備。試(shi)(shi)(shi)重(zhong)(zhong)(zhong)(zhong)(zhong)塊重(zhong)(zhong)(zhong)(zhong)(zhong)量輕(qing)了(le),加(jia)(jia)(jia)(jia)重(zhong)(zhong)(zhong)(zhong)(zhong)前(qian)后(hou)的(de)(de)(de)振(zhen)(zhen)動變化不大(da)(da),計算出誤差較大(da)(da)。試(shi)(shi)(shi)加(jia)(jia)(jia)(jia)重(zhong)(zhong)(zhong)(zhong)(zhong)大(da)(da)小可(ke)(ke)以(yi)按加(jia)(jia)(jia)(jia)重(zhong)(zhong)(zhong)(zhong)(zhong)產生(sheng)的(de)(de)(de)離(li)心力近似等于(yu)1%轉子重(zhong)(zhong)(zhong)(zhong)(zhong)量的(de)(de)(de)原則(ze)來(lai)確定。推(tui)薦方(fang)法(fa)(fa)是:在上述原則(ze)中(zhong),取試(shi)(shi)(shi)加(jia)(jia)(jia)(jia)重(zhong)(zhong)(zhong)(zhong)(zhong)重(zhong)(zhong)(zhong)(zhong)(zhong)量可(ke)(ke)以(yi)偏(pian)輕(qing)一些。無論單面(mian)或雙面(mian)平(ping)衡,首先(xian)記錄初(chu)始振(zhen)(zhen)動的(de)(de)(de)幅(fu)值和相角(jiao),然(ran)后(hou)記錄加(jia)(jia)(jia)(jia)重(zhong)(zhong)(zhong)(zhong)(zhong)后(hou)振(zhen)(zhen)動的(de)(de)(de)幅(fu)值和相角(jiao)。比較前(qian)后(hou)二次振(zhen)(zhen)動的(de)(de)(de)幅(fu)值和相角(jiao)的(de)(de)(de)變化,當幅(fu)值大(da)(da)于(yu)±20%變化,相角大于±20°變(bian)化,就認為試(shi)重(zhong)塊(kuai)重(zhong)量(liang)是合(he)適。如果(guo)振幅變(bian)化不(bu)明顯,就應(ying)加大試(shi)重(zhong)的重(zhong)量(liang)。如果(guo)相位(wei)(wei)變(bian)化不(bu)明顯,就應(ying)重(zhong)新移動試(shi)重(zhong)的位(wei)(wei)置(zhi)。上述所(suo)說是針(zhen)對(dui)著*個轉子(zi)選取試(shi)重(zhong)重(zhong)量(liang)方法(fa),對(dui)于同樣尺寸;同樣大小第二個轉子(zi)只(zhi)要(yao)取*個轉子(zi)巳(si)經計算出(chu)來(lai)轉子(zi)上存(cun)在的不(bu)平衡量(liang)作為試(shi)重(zhong)塊(kuai)大小就可以。

6.9、試重法和影響(xiang)系(xi)數法的運用

對(dui)同(tong)一(yi)轉(zhuan)(zhuan)(zhuan)子(zi)(zi)或同(tong)一(yi)外形尺寸(cun)(cun)、材料(liao)及結構的轉(zhuan)(zhuan)(zhuan)子(zi)(zi),可(ke)以(yi)認為其影響(xiang)(xiang)(xiang)系(xi)(xi)數是不變的。因(yin)此,為提高生(sheng)產效(xiao)率,對(dui)同(tong)一(yi)轉(zhuan)(zhuan)(zhuan)子(zi)(zi)或同(tong)一(yi)外形尺寸(cun)(cun)、材料(liao)及結構的轉(zhuan)(zhuan)(zhuan)子(zi)(zi),在使(shi)用(yong)(yong)(yong)(yong)試重(zhong)法求(qiu)得了其影響(xiang)(xiang)(xiang)系(xi)(xi)數后,就可(ke)以(yi)使(shi)用(yong)(yong)(yong)(yong)影響(xiang)(xiang)(xiang)系(xi)(xi)數法對(dui)這些轉(zhuan)(zhuan)(zhuan)子(zi)(zi)進(jin)行平(ping)衡。使(shi)用(yong)(yong)(yong)(yong)影響(xiang)(xiang)(xiang)系(xi)(xi)數法進(jin)行平(ping)衡省去了加試重(zhong)的步驟。對(dui)*個轉(zhuan)(zhuan)(zhuan)子(zi)(zi)(新轉(zhuan)(zhuan)(zhuan)子(zi)(zi))必須用(yong)(yong)(yong)(yong)試重(zhong)法做(zuo)(zuo)動平(ping)衡,對(dui)于同(tong)樣尺寸(cun)(cun);同(tong)樣大小第二個轉(zhuan)(zhuan)(zhuan)子(zi)(zi)(老(lao)轉(zhuan)(zhuan)(zhuan)子(zi)(zi))可(ke)以(yi)用(yong)(yong)(yong)(yong)影響(xiang)(xiang)(xiang)系(xi)(xi)數法做(zuo)(zuo)動平(ping)衡,前提是手邊有通(tong)過使(shi)用(yong)(yong)(yong)(yong)試重(zhong)法求(qiu)得了其轉(zhuan)(zhuan)(zhuan)子(zi)(zi)影響(xiang)(xiang)(xiang)系(xi)(xi)數記(ji)錄。試重(zhong)法適用(yong)(yong)(yong)(yong)于大型(xing)的單(dan)件的轉(zhuan)(zhuan)(zhuan)子(zi)(zi)做(zuo)(zuo)動平(ping)衡。影響(xiang)(xiang)(xiang)系(xi)(xi)數法適用(yong)(yong)(yong)(yong)于小型(xing)的多(duo)批量的轉(zhuan)(zhuan)(zhuan)子(zi)(zi)做(zuo)(zuo)動平(ping)衡。

6.10、動(dong)平衡測試(shi)過程(cheng)的安全要求

在(zai)動平(ping)衡測試過程,要時(shi)刻注意(yi)安全。振動傳感器下面磁(ci)吸座,轉速傳感器軟管磁(ci)力座,吸力很大,極易夾住手指(zhi),操(cao)作(zuo)應十分注意安全。使用(yong)霍爾傳感器配套小磁鋼一定(ding)要用(yong)502膠水(shui)將其粘牢。使用光電傳感(gan)器(qi)在機器(qi)運轉過程中(zhong)調節傳感(gan)器(qi)的距(ju)離和靈敏度時,一定注意安全(quan)。試重采(cai)用螺釘連接(jie)到轉(zhuan)子(zi),對(dui)于將試重焊(han)接(jie)在轉(zhuan)子(zi)上,一定(ding)要(yao)焊(han)好運轉(zhuan)時不能掉下來。

6.11、剩(sheng)余不平(ping)衡量的(de)選擇標(biao)準

  剩(sheng)余(yu)不平衡量的標準:

對儀器而(er)言,當屏幕上顯示振動(dong)(dong)信(xin)號的(de)上下跳(tiao)動(dong)(dong)幅值超過±30%,上下跳動相角超過±30°。動(dong)平(ping)衡測量就不能(neng)進行。此(ci)時屏(ping)幕(mu)顯(xian)示的配重M就是(shi)轉子的剩余不平(ping)衡量。

如果振(zhen)動信號選用的是振(zhen)動烈度(du)mm/s單位,請參照評級標準。

VT800低轉速雙(shuang)面動(dong)平(ping)衡儀

VT800型現場動平衡測量儀  VT800型現場動平衡測量儀價錢多少

VT800型現場動平衡測量儀采用(yong)大規模集成電路(lu)和單片(pian)機技(ji)術(shu)。該儀器(qi)具(ju)有多功(gong)能性,既(ji)可(ke)作(zuo)轉速表用(yong),又可(ke)作(zuo)振(zhen)動(dong)測試(shi)用(yong)。既(ji)可(ke)作(zuo)時域分析(xi),又可(ke)作(zuo)頻域分析(xi)。特別是具(ju)有測量動(dong)平衡的一切功(gong)能。

該(gai)儀(yi)(yi)(yi)器(qi)操作簡單(dan),人機對(dui)(dui)話(hua),菜單(dan)提(ti)示,測量(liang)數據(ju)可隨時鎖定保持。VT動平(ping)衡儀(yi)(yi)(yi)結構緊湊重量(liang)輕,鍵盤及(ji)顯示屏(ping)在(zai)面板(ban)上(shang)(shang),而輸入(ru)輸出插口及(ji)各種(zhong)控(kong)制開關(guan)均置于面板(ban)上(shang)(shang)。VT800動平(ping)衡儀(yi)(yi)(yi)可以對(dui)(dui)各種(zhong)旋轉機械進行(xing)整機現場(chang)動平(ping)衡,相(xiang)當(dang)于一(yi)臺可移動的動平(ping)衡機。它(ta)設計(ji)精巧(qiao)攜帶方便(bian),整個儀(yi)(yi)(yi)器(qi)裝(zhuang)在(zai)一(yi)只便(bian)攜儀(yi)(yi)(yi)器(qi)箱內。VT800除具有(you)一般的動(dong)平(ping)衡功能外,還針對(dui)臥(wo)式螺旋離心機、碟式離心機類產品的整機動(dong)平(ping)衡進行(xing)特(te)殊設計, 増加(jia)了抗(kang)干擾能力,能夠很方便的測量有(you)差轉(zhuan)速復合(he)轉(zhuan)鼓體(ti)的振(zhen)動(dong)及進行整(zheng)機現(xian)場(chang)動(dong)平衡(heng).

技術(shu)參數

1.一般測量:

轉速測量:           30~30,000 rpm  

普(pu)通振(zhen)動測量(liang):       0.1~5000μm (峰峰值)

0.1~2000mm/s (有效值(zhi))

振動分(fen)析:           FFT  頻譜分(fen)析

顯示方(fang)式:           點(dian)陣圖形(xing) 64X240點(dian)陣圖形(xing)液晶漢化菜(cai)

鍵   盤(pan):            八鍵  

2.動平(ping)衡(heng)測量:

測(ce)量點數(shu):         單(dan)(dan)測(ce)點或單(dan)(dan)面(mian)  雙測(ce)點或雙面(mian)

同頻工作轉速:       100~30,000 rpm

同頻(pin)振幅量程:       0.1~5000μm  (峰峰值)

振動烈度量程:       0.1~2000mm/s  (有效值(zhi))

相位精(jing)度(du):           0-360°±1 °

去(qu)除不平衡率:    ≥95%

目  錄



一、概述  ----------------------------------------------------------------------------------------1

二、技術(shu)參數-------------------------------------------------------------------------------------1

三、動平衡(heng)測量中三個重要要求-------------------------------------------------------------2

3.1、轉速傳感器(qi)的安裝--------------------------------------------------------------------2

3.2、振動傳感器(qi)的(de)安裝--------------------------------------------------------------------2

3.3、相位角的(de)確定(ding)--------------------------------------------------------------------------2

四(si)、對儀器操作中的(de)幾點說(shuo)明----------------------------------------------------------------3

五、測量方法-------------------------------------------------------------------------------------3

5.1、轉速(su)測量(liang)--------------------------------------------------------------------------------4

5.2、振(zhen)動測量--------------------------------------------------------------------------------4

5.3、試重法動平(ping)衡(heng) -------------------------------------------------------------------------4

5.3.1、單面動(dong)平(ping)衡(heng)測(ce)量---------------------------------------------------------------------5

5.3.2、雙面動平測量---------------------------------------------------------------------8

5.4、 影響系數法動(dong)平衡(heng)-----------------------------------------------------------------14

5.4.1、單(dan)面動平衡測量-------------------------------------------------------------------14

5.4.2、雙面動平衡測量-------------------------------------------------------------------15

5.5、 動平(ping)衡計(ji)算 ------------------------------------------------------------------------17

5.5.1、單(dan)平(ping)面動(dong)平(ping)衡計算(suan)----------------------------------------------------------------17

5.5.2、雙(shuang)平面動(dong)平衡(heng)計(ji)算(suan)----------------------------------------------------------------18

5.6、信(xin)號分析 ----------------------------------------------------------------------------19

六(liu)、動(dong)平衡測量(liang)中(zhong)的若干問題(ti)--------------------------------------------------------------22

  6.1、確認轉(zhuan)子設備是否有(you)不平衡(heng)引(yin)起振(zhen)動(dong)------------------------------------------22

6.2、動(dong)平衡儀對設備的(de)基本要求------------------------------------------------------22

6.3、如何提高動平衡儀測量精(jing)度------------------------------------------------------22

6.4、動(dong)平(ping)衡(heng)儀(yi)與動(dong)平(ping)衡(heng)機的區別------------------------------------------------------22

6.5、三種(zhong)轉速傳感(gan)器的比較------------------------------------------------------------22

6.6、如何(he)克服小磁鋼附加(jia)質(zhi)量的影(ying)響------------------------------------------------23

6.7、傳感器(qi)數值穩定是動平衡(heng)測量的關鍵------------------------------------------23

6.8、試(shi)(shi)重(zhong)(zhong)(zhong)法中(zhong)試(shi)(shi)重(zhong)(zhong)(zhong)的重(zhong)(zhong)(zhong)量和角度(du)合(he)理確定(ding)------------------------------------------23

6.9、試重法和(he)影響系數法的(de)運用------------------------------------------------------23

6.10、動平衡測試過程的安(an)全要求----------------------------------------------------24

6.11、剩余不平衡量的(de)選擇(ze)標(biao)準-------------------------------------------------------24

七、儀器(qi)基本配(pei)置

離心機動平衡測量儀


留言框

  • 產品:

  • 您的單位:

  • 您的姓名:

  • 聯系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請(qing)輸入(ru)計算結(jie)果(guo)(填寫阿拉伯數字),如(ru):三(san)加四(si)=7