ZC-90系列絕(jue)(jue)緣電(dian)(dian)(dian)(dian)阻(zu)測量儀(yi)是測試電(dian)(dian)(dian)(dian)工(gong)絕(jue)(jue)緣材料;電(dian)(dian)(dian)(dian)線電(dian)(dian)(dian)(dian)纜;防靜電(dian)(dian)(dian)(dian)工(gong)程(cheng)電(dian)(dian)(dian)(dian)阻(zu)測量以及其(qi)他電(dian)(dian)(dian)(dian)工(gong)制(zhi)品絕(jue)(jue)緣電(dian)(dian)(dian)(dian)阻(zu)的理想儀(yi)器(qi)。本儀(yi)器(qi)采(cai)用了超高阻(zu)、微電(dian)(dian)(dian)(dian)流(liu)器(qi)件,具(ju)有測量精(jing)度高;分辨(bian)力強(qiang);抗干擾能力強(qiang);讀(du)數穩定性(xing)好;體(ti)積小攜帶、使用方便(bian);電(dian)(dian)(dian)(dian)池通用性(xing)強(qiang)的優點(dian)。

型號:

瀏覽量:1069

更新時間:2023-11-22

價格:4500

在線留言
品牌其他品牌供貨周期現貨
主要用途電纜測試 產品電阻率測試 防靜電測試應用領域環保,石油,能源,電子,交通

ZC-90系列高絕緣電(dian)阻測量儀性能特點及用途介紹

ZC-90系(xi)列高絕緣電阻測(ce)量儀

ZC-90F高絕緣電阻測量儀使用方法

ZC-90F高絕緣電阻測量儀

4.4.1 儀表與被測器件的連接

在開(kai)始操(cao)作前(qian), 儀表電源應處于關閉位置, 在前(qian)一次測量(liang)結(jie)束(shu)后,應經過30秒左右的內(nei)部(bu)放(fang)電時間, 以確保(bao)操(cao)作人員免(mian)受高(gao)壓電擊。

4.4.1.1將被(bei)測器件(jian)的(de)兩端分別與(yu)儀(yi)表的(de)高(gao)壓(ya)輸出端與(yu)測量輸入端(黑(hei)(hei)線(xian)(xian)紅(hong)夾(jia)子(zi))相連,保(bao)(bao)護環與(yu)屏蔽(bi)(bi)端(黑(hei)(hei)線(xian)(xian)黑(hei)(hei)夾(jia)子(zi))相連,如被(bei)測器件(jian)無保(bao)(bao)護環則屏蔽(bi)(bi)端空置。注意:測量輸入端(黑(hei)線紅夾子)除(chu)了與被測器(qi)件連接(jie)外,必須*懸空,與其他任何物體的(de)接(jie)觸將會嚴重影(ying)響高阻測量的(de)準確性。

4.4.1.2單芯(xin)電(dian)(dian)線絕緣電(dian)(dian)阻測(ce)量: 將被測(ce)電(dian)(dian)線放入恒溫水箱中(電(dian)(dian)線兩頭放在水箱外),儀表高壓輸出端通(tong)過金屬導體與(yu)水接通(tong),測(ce)量輸入端(紅(hong))與(yu)芯(xin)線相連,屏蔽端(黑)空置不用,見圖7。

4.4.1.3多芯及有(you)金(jin)屬外套的電(dian)纜絕緣電(dian)阻測量:測量輸入端(duan)(紅)與被測芯線相連,將(jiang)其它芯線與外套 ( 電(dian)纜屏蔽層 ) 連在(zai)一起后與儀表的高壓端(duan)連接,屏蔽端(duan)(黑)空置不用,見圖8。                                                              

4.4.1.4 防(fang)靜(jing)電(dian)(dian)(dian)(dian)工(gong)程(cheng)表(biao)(biao)面(mian)電(dian)(dian)(dian)(dian)阻測(ce)量:  與(yu)防(fang)靜(jing)電(dian)(dian)(dian)(dian)工(gong)程(cheng)電(dian)(dian)(dian)(dian)阻測(ce)量標(biao)準電(dian)(dian)(dian)(dian)極(ji)(ji)配套(tao)使用(選(xuan)購件(jian)),將儀(yi)表(biao)(biao)的(de)(de)高(gao)壓(ya)輸出端與(yu)測(ce)量輸入(ru)端分別(bie)與(yu)兩個(ge)(ge)電(dian)(dian)(dian)(dian)極(ji)(ji)相(xiang)(xiang)連接(屏(ping)蔽端空置不用),剝去電(dian)(dian)(dian)(dian)極(ji)(ji)下(xia)表(biao)(biao)面(mian)黑色(se)導(dao)電(dian)(dian)(dian)(dian)膜上的(de)(de)保護膜(黃色(se))后,將兩個(ge)(ge)電(dian)(dian)(dian)(dian)極(ji)(ji)相(xiang)(xiang)隔(ge)一(yi)定距離(li)置于被測(ce)物體表(biao)(biao)面(mian)(如測(ce)量防(fang)靜(jing)電(dian)(dian)(dian)(dian)地(di)板,相(xiang)(xiang)隔(ge)距離(li)一(yi)般(ban)為30cm),見圖9。注(zhu)意:測(ce)量過程(cheng)中不得接觸(chu)電極的(de)金屬面,以免受到(dao)高壓電擊。注意保證(zheng)導電膜(mo)表(biao)面清潔(jie)平整(zheng),測量(liang)完畢應(ying)將(jiang)保護膜(mo)貼上(shang)(shang),然后放在(zai)光滑(hua)平整(zheng)的表(biao)面上(shang)(shang),如有臟污(wu),切忌(ji)利器(qi)檫(cha)刮,可以用普通封箱膠(jiao)帶在(zai)導電膜(mo)表(biao)面粘吸,將(jiang)臟物粘去(qu)。

  如果被測物體的表(biao)面(mian)不是平(ping)(ping)面(mian),則(ze)可用(yong)導電(dian)膠在(zai)被測物體表(biao)面(mian)的相(xiang)應位(wei)置(zhi)涂上(shang)兩(liang)行(xing)平(ping)(ping)行(xing)的膠條(tiao),然后將儀表(biao)的高壓輸(shu)出端(duan)與(yu)測量輸(shu)入端(duan)分別(bie)與(yu)兩(liang)個導電(dian)膠條(tiao)相(xiang)連接(屏蔽端(duan)空(kong)置(zhi)不用(yong))。

4.4.2 打(da)開(kai)(kai)電源開(kai)(kai)關(guan)。

4.4.3將倍率(量程(cheng))開關置于 低檔位(wei),儀(yi)表校零(見4.3.3節)。

ZC-90、 90A、90D、 90E、90F、90G的(de) 低倍率為×105Ω,ZC-90B、 90C為(wei)×104Ω,電阻測量必須(xu)從 低(di)量程開(kai)始,這是因為(wei)被測物(wu)體(ti)可能(neng)有很大的分布電(dian)容,由此導致的充電(dian)電(dian)流可能(neng)會在開始測量的瞬間(jian)對儀(yi)表高(gao)靈敏的輸入(ru)端造成危(wei)害。


圖9 防靜電工程表(biao)面電阻測量

其中:

1. 儀表(biao)高壓輸出端                    ;             10. 被測單芯電纜

2. 儀表(biao)測量(liang)輸(shu)入(ru)端                                 11. 被測芯線

3. 屏蔽(bi)端夾子 (黑(hei)(hei)線黑(hei)(hei)夾子)                         12. 其(qi)他芯線

4. 輸入端夾(jia)子 (黑線紅(hong)夾(jia)子)                         13. 連接線

5. 高壓端(duan)夾子 (紅(hong)線紅(hong)夾子,90G為黑色屏蔽線)       14. 電纜屏蔽層(或金屬外套)

6. 連接線                                         15. 被測多(duo)芯電纜

7. 金屬導體                                       16. 防(fang)靜(jing)電工程電阻(zu)測量標準電極

8. 恒溫水(shui)浴箱 (圖中未包括恒溫部分)                 17. 導電膜

9. 水(shui)                                             18. 被測材料




4.4.4 選擇合適的測量(liang)電壓

  測(ce)(ce)量電(dian)(dian)(dian)(dian)壓(ya)(ya)的(de)(de)(de)(de)選擇(ze)是由被測(ce)(ce)物(wu)體的(de)(de)(de)(de)特性以及測(ce)(ce)量本(ben)身(shen)的(de)(de)(de)(de)技術規范而(er)確定的(de)(de)(de)(de), 不(bu)同的(de)(de)(de)(de)測(ce)(ce)量電(dian)(dian)(dian)(dian)壓(ya)(ya)可能導致不(bu)同的(de)(de)(de)(de)測(ce)(ce)量結果,這是因為(wei)絕緣體的(de)(de)(de)(de)導電(dian)(dian)(dian)(dian)機理與(yu)金屬的(de)(de)(de)(de)導電(dian)(dian)(dian)(dian)機理有本(ben)質上的(de)(de)(de)(de)不(bu)同,因此(ci),除(chu)了特制的(de)(de)(de)(de)標(biao)準電(dian)(dian)(dian)(dian)阻外,一般的(de)(de)(de)(de)被測(ce)(ce)對象都(dou)有較高的(de)(de)(de)(de)負(fu)電(dian)(dian)(dian)(dian)壓(ya)(ya)系(xi)數(shu),即測(ce)(ce)量電(dian)(dian)(dian)(dian)壓(ya)(ya)越高,電(dian)(dian)(dian)(dian)阻讀數(shu)越小。將高壓(ya)(ya)選擇(ze)開關(guan)撥至相應的(de)(de)(de)(de)電(dian)(dian)(dian)(dian)壓(ya)(ya)檔位(wei)就(jiu)可以獲得所(suo)需的(de)(de)(de)(de)測(ce)(ce)量電(dian)(dian)(dian)(dian)壓(ya)(ya)。注意(yi):由于儀表(biao)內(nei)部高壓(ya)(ya)電(dian)容(rong)的(de)儲(chu)能較大(da),內(nei)部放電(dian)時間要30秒左右,因此從一種測量(liang)(liang)(liang)電(dian)壓(ya)(ya)時改變為(wei)另一種測量(liang)(liang)(liang)電(dian)壓(ya)(ya)時,功能開(kai)(kai)關必須先(xian)放在“放電(dian)調零"檔位,30秒后才能開(kai)(kai)始(shi)新選擇的(de)電(dian)壓(ya)(ya)的(de)測量(liang)(liang)(liang),否則(ze)測量(liang)(liang)(liang)電(dian)壓(ya)(ya)可能大(da)幅度高于額定(ding)值,損壞被測器(qi)件,在電(dian)壓(ya)(ya)未到達額定(ding)值之前,儀表(biao)讀(du)數也不正確。

4.4.5倍(bei)率(量程)選擇

  (ZC-90,90A,90B,90C)將功能開(kai)關(guan)(16)由“調(diao)零"檔經“放電(dian)(dian)"、“充(chong)電(dian)(dian)"檔撥至(zhi)“測(ce)(ce)量"檔位, 測(ce)(ce)量電(dian)(dian)壓(ya)施加在(zai)被測(ce)(ce)對象上(shang),電(dian)(dian)阻測(ce)(ce)量開(kai)始;

   ZC-90(新版)、90D、90E,90F將將高壓(校零)選擇開關(15)由“放電校零"檔經“充電"檔撥至所選的電壓檔位,測量(liang)電壓施加在被測對象上(shang),電阻測量(liang)開始;

   ZC-90G將“電池(chi)測(ce)量"選(xuan)擇開關(20)撥至“測(ce)量"檔位,將 “電流電(dian)(dian)(dian)阻"選(xuan)擇開(kai)關(21)撥至“電(dian)(dian)(dian)阻"檔(dang)位(wei),此時顯示屏上出現(xian)“R(Ω)"字(zi)符(fu),說明儀(yi)表進入電(dian)(dian)(dian)阻測(ce)(ce)(ce)(ce)量(liang)狀態,將高壓(校零(ling))選(xuan)擇開(kai)關(15)由(you)“000" (校零(ling)、放電(dian)(dian)(dian))檔(dang)撥至所(suo)選(xuan)的電(dian)(dian)(dian)壓檔(dang)位(wei),測(ce)(ce)(ce)(ce)量(liang)電(dian)(dian)(dian)壓施加在被測(ce)(ce)(ce)(ce)對(dui)象上,電(dian)(dian)(dian)阻測(ce)(ce)(ce)(ce)量(liang)開(kai)始(shi)。

注(zhu)意觀(guan)察儀表示(shi)值(zhi),如顯(xian)示(shi)屏出現“1"(單*個“1"字后面沒讀(du)數(shu))說明(ming)儀表(biao)量(liang)(liang)程過小。逐步將(jiang)倍(bei)率(量(liang)(liang)程)開關按順時針方向旋轉(zhuan),當(dang)儀表(biao)出(chu)現讀(du)數(shu)后應立(li)即停止轉(zhuan)動。通常, 儀表示值應在100個字至1999個字之間(忽(hu)略小數點(dian)),如果示值小于(yu)100個字,可以(yi)將倍(bei)率(lv)(量程)開關按(an)逆時針方向旋轉一檔, 以(yi)求(qiu)得 佳的準確度與分辨力。如顯示屏上(shang)出現“:"符號(hao)(ZC-90,90A,90B,90C)或“×"符號(hao)(ZC-90新、90D、90E、90F、90G)及報警蜂鳴聲(ZC-90G),說明儀表處于量程過大(da)狀態,應(ying)迅速將量程(倍率)開(kai)關逆時針方向(xiang)旋轉,如在 低倍率檔仍出現“ : "或(huo)“×"符號,說(shuo)明(ming)被測(ce)器件短(duan)路,請速將(jiang)開(kai)關(guan)撥至(zhi)“校零"“放電校零"或“.000"檔位,斷開電阻測(ce)量回路(lu)。注(zhu)意(yi):出現: "或“×"符號時(shi),儀表讀數(shu)無效(xiao)。儀表輸入端受到過電流的沖擊,零(ling)位(wei)可(ke)能暫時(shi)偏移,通常放置一段時(shi)間可(ke)以恢(hui)復(fu)。

被測對象(xiang)的絕緣電阻(zu) = 儀(yi)表示值×倍率                        

4.4.6 被測器件放電

測(ce)量結束后,(ZC-90,90A,90B,90C)將功能(neng)開關(guan)(16)撥至“放(fang)電"或“校零(ling)"位置;(ZC-90新、90D、90E、90F、90G)將開(kai)關(guan)(15)撥至“.000"檔位,斷(duan)開(kai)測量電(dian)壓(ya),并接通放電(dian)回路,經過1520 秒(miao),被測(ce)器件充分放電(dian)后,操作人員方可接(jie)觸(chu)高壓端(duan)(duan)與測(ce)量端(duan)(duan)。                                                                                              

4.4.7 電(dian)線電(dian)纜(lan)每公里長度絕(jue)緣電(dian)阻按下(xia)式換算(suan)                                          

RL = RX L

式中: RL每公里(li)長度絕緣電(dian)阻,MΩ· km ;     RX試樣絕緣電阻(zu),MΩ;L試樣長度,km

4.5 電阻測量(liang)各量(liang)程(cheng)有效測量(liang)范圍及高(gao)分辨力(li)

各量(liang)程范(fan)圍除了與倍率有關(guan)以外還與不(bu)同(tong)測量(liang)電壓時小數點的位置(zhi)有關(guan),如小數點(dian)在  高位, 測量范(fan)圍(wei)為(0.100-1.999)×倍(bei)率,例:被(bei)測電阻在1.5×109Ω左右,倍率應選109Ω,電阻在3×109Ω,倍率應(ying)選1010Ω,儀表示值為0.300×1010Ω;如小數點在(zai)第2位, 測(ce)量范(fan)圍為(1.00-19.99)×倍(bei)率;如小數點在第3位, 測量(liang)范(fan)圍為(10.0-199.9)×倍率,例:被(bei)測電阻在1.5×109Ω,倍率(lv)可選108Ω,儀表示值為15.0×108Ω,倍率也可選108Ω,儀表示值為150.0×107Ω,分辨率更高(gao);除了(le) 低量程外,儀表的(de)其他量程并非從(cong)0開始,下列(lie)各表規定了(le)各量程的(de)有效測(ce)(ce)量范圍,及各測(ce)(ce)量電壓下的(de) 高(gao)分辨力, 注意:當儀表讀數(shu)小于(yu)表中(zhong)所列(lie)數(shu)值時,只要顯示屏上不出(chu)現: "或“×"符號,讀數仍然(ran)有效