發電機、電動(dong)機的(de)超(chao)低頻耐壓試驗方法

對發電機的超低頻耐壓(ya)試驗操(cao)作(zuo)方(fang)(fang)法與以上對電纜的操(cao)作(zuo)方(fang)(fang)法相似。下(xia)面就不同的地(di)方(fang)(fang)作(zuo)重點補充說明。

1.在交接、大修、局部更換繞組(zu)以及(ji)常(chang)規試驗時,均(jun)可進行此(ci)項試驗。用0.1Hz超(chao)低(di)頻對電(dian)(dian)(dian)(dian)機進(jin)行耐壓(ya)(ya)(ya)試驗,對發電(dian)(dian)(dian)(dian)機端(duan)部絕(jue)緣的(de)(de)缺陷(xian)比工(gong)頻耐壓(ya)(ya)(ya)試驗更(geng)有效。其原因是在工(gong)頻電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)下,由于從線棒流(liu)(liu)出的(de)(de)電(dian)(dian)(dian)(dian)容(rong)電(dian)(dian)(dian)(dian)流(liu)(liu)在流(liu)(liu)經絕(jue)緣外面的(de)(de)半導體防(fang)暈層時造成了較大(da)的(de)(de)電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)降,因而使端(duan)部的(de)(de)線棒絕(jue)緣上(shang)(shang)承受的(de)(de)電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)減小;而在超(chao)低(di)頻情況下,此電(dian)(dian)(dian)(dian)容(rong)電(dian)(dian)(dian)(dian)流(liu)(liu)大(da)大(da)減小了,半導體防(fang)暈層上(shang)(shang)的(de)(de)壓(ya)(ya)(ya)降也大(da)為(wei)減小,故(gu)端(duan)部絕(jue)緣上(shang)(shang)電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)較高,便于發現缺陷(xian)。

2.連線方法:試(shi)驗時應(ying)分相進行,被試(shi)相加壓,非(fei)被試(shi)相短接(jie)接(jie)地。如圖14所示

3.按(an)照有關規(gui)程的要求,試驗電壓(ya)峰值(zhi)可按(an)如下公式(shi)確定:

maxβKUo

        其中Umax :為0.1Hz試驗電壓(ya)的峰(feng)值(kV

β:0.1Hz與50Hz電壓的(de)等效(xiao)系(xi)數,按我國規程的(de)要求,取1.2

K:通常取1.3~1.5   一般取1.5

o :發(fa)電(dian)機定(ding)(ding)子繞組額定(ding)(ding)電(dian)壓(kV

     例如:額定(ding)電(dian)壓為(wei)13.8 kV的發電機(ji),超低頻的試驗電壓峰值計算方法為:

max×1.2×1.5×13.835.1(kV)

  4. 試驗時間(jian)按有(you)關規程進行

5.在耐(nai)壓過程中,若無(wu)異常聲響、氣味、冒煙以及數據顯示(shi)不穩定等現象(xiang),可(ke)以認為絕緣耐(nai)受住了試驗的(de)考驗。為了更好地了解絕緣情況,應盡可(ke)能(neng)全面監(jian)視(shi)絕緣的(de)表面狀態,特別(bie)是空冷機(ji)組。經驗指出,外觀(guan)監(jian)視(shi)能(neng)發(fa)現儀表所不能(neng)反映的(de)發(fa)電(dian)機(ji)絕緣不正常現象(xiang),如表面電(dian)暈、放電(dian)等。

 

 

 

         圖14 測(ce)量定子(zi)的某相連線圖